Last Modified: 11-29-2007 1.6 J
Service Category: Vehicle Interior Section: Meter/Gauge/Display
Model Year: 2008 Model: Sequoia Doc ID: RM000002ZM5006X
Title: METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM: DESCRIPTION (2008 Sequoia)

Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the combination meter. This circuit provides 2 power source types: one is a constant power source mainly used as a backup power source, and other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU. However, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch is ON, the indicator will not operate.

WIRING DIAGRAM



INSPECTION PROCEDURE

PROCEDURE

1.

INSPECT FUSE (MET, MET-B)


(a) Remove the MET and MET-B fuses from the engine room relay block.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

MET fuse

Always

Below 1 Ω

MET-B fuse

Always

Below 1 Ω

OK

2.

CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY AND BODY GROUND)


(a) Disconnect the H37 meter connector.

(b) Measure the resistance and voltage according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

H37-40 (E1) - Body ground

Always

Below 1 Ω

Standard Voltage:

Tester Connection

Switch Condition

Specified Condition

H37-18 (B) - Body ground

Always

11 to 14 V

H37-20 (IG+) - Body ground

Ignition switch ON

11 to 14 V

OK